Inhand - Industrial Router
Brand: Inhand
Photos:
Technology used
WiFi、4G、5G
Target market:
EU, North America, Canada, Australia, Middle East countries, South American countries (Brazil).
Other Partners:
Rocktech
Hongdian
Testing Standards:
country |
RF |
EMC |
SAR |
Safety |
Europe |
EN301511 EN 301 908-1 EN 301 908-2 EN 301 908-13 |
EN 301 489-1 V2.2.3 EN 301 489-52 V1.1.2 |
EN 50360:2017 EN 50566:2017 EN 62209-1:2016 EN 62209-2: 2010/A1:2019 |
EN62368-1:2014+A11:2017 |
United States |
FCC Part2 FCC Part22 FCC Part24 FCC Part27 |
FCC Part15B |
FCC Part2.10
93 FCC Part2.1091 |
NA |
Canada |
RSS-130 Issue 2 RSS-132 Issue 3 RSS-133 Issue 6 RSS-139 Issue 3 RSS-140 Issue 1 RSS-199 Issue 3 |
IC ES 003 |
RSS-102 Issue 5 |
NA |
Japan |
Article 2 Paragraph 1 Item (11)-3(XZ) Article 2 Paragraph 1 Item (11)-7(MW) Article 2 Paragraph 1 Item (11)-19 Article 2 Paragraph 1 Item 21-3 Article 2 Paragraph 1 Item 54 |
MIC Notice No.88 Annex 79 |
PSE |
|
China |
YD/T 2577-2013 YD/T 2578.2-2013 工信部无函[2015]135号, 工信部无函[2015]136号, 工信部无函[2016]193号, 工信部无函[2016]507号 |
NA |
CCC |
|
Australia |
AS/CA S042.1:2018 AS/CA S042.4:2018 |
AS/NZS 2772.2-2016 |
AS/NZS 62368.1:2018 |
Service Experience:
1. As we all know that most of the industrial routers use wireless modules, and once the modules have certification, We will provide customers with the best certification solutions during consultation to save certification costs.
2. For industrial routers with modules certified by FCC, many customers are confused to use FCC ID labels. HTW lab has 20 years of professional experience in FCC certification, supply you a clear and correct labeling demo.
3. China is the most important customer market and manufacture gathering place, for Industrial Routers, they must be certified by CCC and SRRC. HTW lab (member of CCIC group) is the only lab with China prefix, with CCC testing qualifications (CCC is branch of CCIC), and is also a professional SRRC service organization, we are different with other national owned labs because we can provide preliminary testing and debugging services to help with product market access.
HTW Experience:
1. The number of prototypes should be guaranteed:
one fixed-frequency machine with welding wire,
one fixed-frequency machine without welding wire,
and one normal prototype.
2. About fixed frequency (non-signaling mode):
Detailed fixed frequency operation steps and test software are needed,
both modulation wave and single carrier should support adjustment.
3: The target power and antenna gain should be provided in time, because many test software are adjustable power.
4: Regarding to the port of the prototype and user manual, it is best to provide simple documents to help understand and arrange EMC testing.
Samples/prototypes needed:
fixed frequency sample :2 sets
Complete sample:2 sets
Documents Required
Non-technology documentation |
User manual Label ISO certification of manufacturer (optional) |
Technology documentation |
Schematics Operational description Block diagram BOM PCB Layout / PCB placement (optional) Antenna specification (optional) |
Test Site/Equipment:
1, TS 8987(R&S) WiFi
2, Anechoic chamber(3m)
3, CMW500(R&S)
4, Safety test site